Product Details:
Minimum Order Quantity | 1 Piece |
Grade | Industrial , Commercial |
Supply power | AC 220V+/-10% |
Gross weight | 23 kg |
Temperature | 10 degree C TO 50 degree C |
Frequency | 50/60Hz |
Size | 17.5 x 13 x 7.5 |
1 | SUPPLY VOLTAGE | 230± 10% Volts, 50 / 60 Hz, AC Single Phase. | |||
2 | SELECTION (MODE) | All Outputs are connected through by – pass / control mode switch | |||
3 | BY - PASS MODE | If “By pass” - mode is chosen then all outputs will be directly connected to the output terminals. In this option Timer is in “OFF” mode & “ON / OFF” Push button control is in “OFF” position. | |||
4 | CONTROL MODE | If “Push button” control mode is chosen then all outputs will be connected to the output terminals through the “ON/OFF” push button, according to the selection. In this option timer is in “ON” mode. | |||
5 | CURRENT OUTPUT | 0.6 to 2A AC (Measured by external Clamp meter) | |||
6 | A.C VOLTAGE OUTPUT | 10 – 230 V AC With 2A control fuse. | |||
7 | RATING | Continuous | |||
8 | PROTECTION | Fuse for Mains Input and all Outputs | |||
9 | CONSTRUCTION | Powder coated MS Box with Carrying handle. | |||
10 | DIMENSIONS | W x D x H: 17.5” x 13” x 7.5” approx. | |||
11 | WEIGHT | 23 kgs.approx. |
Product Details:
Channels | Testingequipment |
Material | Plastic |
Brand | Anandha jothi |
Relay Type | Singlephase |
Current Output | 30A |
RLY 360
WE are leading manufacturers, exporters and trader of Electronic Testing Equipment. Well recognized for delivering high performance & accuracy standards, these find usage in meeting the calibration needs of LT/ HT/ EHT Distribution Substations. The product range we offer includes Testing Equipment, Electrical Testing Equipment, and Frequency Voltage Generator. Further, we ensure that these testing equipment are designed and developed by our highly experienced and qualified engineers, who possess complete knowledge of market needs so as to meet the specific demands of our customers.
With the assistance of our expert engineers, we are able to meet the varied demands of our clientele. Our organization has set up a robust infrastructure, which provides us the capacity of manufacturing premium quality products in compliance with industry standards. In order to attain optimum client satisfaction, we offer the entire range of products at customized packaging options, coupled with affordable pricing. We are exporting our quality products in UAE and Singapore.
Backed by 10 years of rich industry experience, our business operations are led by Mr. Mahehdran, who has with him rich experience in the involved business operations. His visionary approach, as well as dedicated service support of experienced industry professionals also, ensures that the solutions offered by us deliver optimum functionality in the given situation.
Product Details:
Current Output | 30A AC |
Relay Type | Relay test kit-30A |
Relay Voltage | 230V AC/230V DC |
Brand | AJI |
Material | Rugged Case Plastic |
Relay Current | 30a |
Country of Origin | Made in India |
Product Details:
Minimum Order Quantity | 1 Piece |
Gross weight | 35kg |
Voltage | 220Volts, 50 Hz, (+/-10%) |
SUPPLY VOLTAGE | 230 10% Volts 50 60 Hz AC Single Phase |
External Timer | for checking breaker opening and closing time |
Power | 2x250VA max |
Distortion | Less than or equal to 0.8% |
Usage | Industrial |
Product Details:
Distortion | Less than or equal to 0.5% |
Power | 2x250 kVA max |
AC output (effective value) | 0~40A |
Gross weight | 33kg |
Power Source | Electricity |
Usage | Industrial |
Product Details:
SUPPLY VOLTAGE | 230 Volts 50 Hz 10 AC Single Phase supply through Toggle switch Control Fuse for Units 1 2 |
CONTROLS | 1ST Unit with Push Button Control Only When the ON/OFF push button is operated all outputs will b |
AMMETER | 3 Digit 12mm LED type. Accuracy 1 Direct reading 0 50 A For current ranges of 1A,5A,10A,25A |
DC SOURCE | Variable DC Source 0 240 V DC 2 A by Separate Variac continues rating |
VOLTAGE OUTPUT | 0 230 V AC 2A Variable voltage output through fuse units Separate pair of test terminals is provide |
RATING | Continuous 3min ON 10 Min OFF |
PROTECTION | Control Fuse for Mains input and all outputs Voltage |
TIME INTERVAL METER | 5 Digit 12 mm LED crystal time base. One five digit timer with toggle selector for NO/NC for checkin |
FEATURES | Independent Digital readouts of current voltage and time The kit can be used for all types o |
OUTPUT | Variable current Application 0 100A AC For voltage the Variac output is connected to variable v |
MODELRLY – 801-1SUPPLY VOLTAGE230± 10% Volts, 50 / 60 Hz, AC Single Phase.-2SELECTION (MODE)All Outputs are connected through by – pass / control mode switch-3BY - PASS MODEIf “By pass” - mode is chosen then all outputs will be directly connected to the output terminals. In this option Timer is in “OFF” mode & “ON / OFF” Push button control is in “OFF”
position.-4CONTROL MODEIf “Push button” control mode is chosen then all outputs will be connected to the output terminals through the “ON/OFF” push button, according to the selection. In this option timer is in “ON”
mode.-5CURRENT OUTPUT0 to 2A AC (Measured by external Clamp meter)-6A.C VOLTAGE OUTPUT0 – 230 V AC With 2A control fuse.-7RATINGContinuous-8PROTECTIONFuse for Mains Input and all Outputs-9CONSTRUCTIONPowder coated MS Box with Carrying handle.-10DIMENSIONSW x D x H: 17.5” x 13” x 7.5” approx.-11WEIGHT23 kgs.approx.Accessories(charges applicable) :- Model : RLY – 8011. Test Cable (Current Cable) 2 Meters long with Crocodile Clip : 1 Set2. Test Cable (AC Voltage Cable) 2 Meters long with Crocodile Clip : 1 Set 3. DC Voltage Cable 2 Meters long with Crocodile Clip : 1 Set 4. Test Cable (Timer) 2 Meters long with Crocodile Clip : 1 Set5. Mains Card 2 Meter : 2 Nos.6. Spare Fuse 4 A (Main Fuse ) – 2 Nos.7. Spare Fuse 2 A (Main Fuse ) – 10 Nos.8. Instruction Manual – 1 No.9. Calibration Certificate – 1 No.
Two separate inputs & five outputs
Test outputs available:
Unit – I : 0 to 100 A, AC, 0 to 240 volts AC
0 to 240 volts DC. , Separate Variable Source
Unit – II: 0 to 2 A AC, 0 to 240 volts AC and aux.
Panel with clear and easy to follow legend.
Built in Timer for testing relays and circuit breakers.
Product Details:
Power | 2x250VA max |
Voltage | 230 Volts (+/-10%) |
Frequency | 50 hz |
Power Source | Electricity |
Distortion | Less Than or Equal To 0.5% |
Gross weight | 33 kg |
Product Details:
AMMETER | 3 Digit 12mm LED type Accuracy Direct reading 0 100A For current ranges of 1A 5A 10A 25A and 50A AC |
MODEL | RLY – 108 | ||
1 | SUPPLY VOLTAGE | 230 Volts , 50 Hz, (± 10%), AC Single Phase supply through Toggle switch & Control Fuse for Units 1 & 2. | |
2 | OUTPUT | 1. Variable current Application 0.6 – 100A AC 2. For voltage, the Variac output is connected to variable voltage output 0 – 230 V AC with fuse. 3. Separate current output terminals and separate voltage output terminals are provided (At one time either current or voltage circuit will be connected through a Toggle Switch) |
|
3 | CONTROLS | 1. 1ST Unit with Push Button Control Only. When the ON/OFF push button is operated, all outputs will be connected to the output connectors 2. 2nd unit with Push Button Control & By-Pass Switch |
|
4 | CURRENT OUTPUT | Output : 0.6 – 100A / 50A / 25A / 10A / 5A / 1A Each of these outputs has a separate terminal referred to one common terminal. Each current output terminal is for 400 VA capacity, except 1A output which is for 250 VA capacity |
|
5 | VOLTAGE OUTPUT | 10-230 V AC / 2A – Variable voltage output through fuse units Separate pair of test terminals is provided | |
6 | RATING | Continuous (3min ON / 10 Min. OFF) | |
7 | BRAND Get Best Price Of The Protective Relay Test Kit 109 For Rs.62000/- |
Anandha Jothi Industries |
Product Details:
DC voltage output | Value/ Range |
Output Accuracy | 0.5 grade |
Current output | 0~45A/each phase, 0~120 |
Voltage | 20V |