Product Details:
Minimum Order Quantity | 1 Piece |
Size | 17.5 x 13 x 7.5 |
Supply power | AC 220V+/-10% |
Gross weight | 23 kg |
Temperature | 10 degree C TO 50 degree C |
Frequency | 50/60Hz |
Grade | Industrial , Commercial |
1 | SUPPLY VOLTAGE | 230± 10% Volts, 50 / 60 Hz, AC Single Phase. | |||
2 | SELECTION (MODE) | All Outputs are connected through by – pass / control mode switch | |||
3 | BY - PASS MODE | If “By pass” - mode is chosen then all outputs will be directly connected to the output terminals. In this option Timer is in “OFF” mode & “ON / OFF” Push button control is in “OFF” position. | |||
4 | CONTROL MODE | If “Push button” control mode is chosen then all outputs will be connected to the output terminals through the “ON/OFF” push button, according to the selection. In this option timer is in “ON” mode. | |||
5 | CURRENT OUTPUT | 0.6 to 2A AC (Measured by external Clamp meter) | |||
6 | A.C VOLTAGE OUTPUT | 10 – 230 V AC With 2A control fuse. | |||
7 | RATING | Continuous | |||
8 | PROTECTION | Fuse for Mains Input and all Outputs | |||
9 | CONSTRUCTION | Powder coated MS Box with Carrying handle. | |||
10 | DIMENSIONS | W x D x H: 17.5” x 13” x 7.5” approx. | |||
11 | WEIGHT | 23 kgs.approx. |
Product Details:
Usage | Industrial |
Distortion | Less than or equal to 0.5% |
Power | 2x250 kVA max |
AC output (effective value) | 0~40A |
Gross weight | 33kg |
Power Source | Electricity |
Product Details:
TIME INTERVAL METER | 5 Digit 12 mm LED crystal time base. One five digit timer with toggle selector for NO/NC for checkin |
FEATURES | Independent Digital readouts of current voltage and time The kit can be used for all types o |
OUTPUT | Variable current Application 0 100A AC For voltage the Variac output is connected to variable v |
CONTROLS | 1ST Unit with Push Button Control Only When the ON/OFF push button is operated all outputs will b |
VOLTAGE OUTPUT | 0 230 V AC 2A Variable voltage output through fuse units Separate pair of test terminals is provide |
RATING | Continuous 3min ON 10 Min OFF |
AMMETER | 3 Digit 12mm LED type. Accuracy 1 Direct reading 0 50 A For current ranges of 1A,5A,10A,25A |
PROTECTION | Control Fuse for Mains input and all outputs Voltage |
DC SOURCE | Variable DC Source 0 240 V DC 2 A by Separate Variac continues rating |
SUPPLY VOLTAGE | 230 Volts 50 Hz 10 AC Single Phase supply through Toggle switch Control Fuse for Units 1 2 |
MODELRLY – 801-1SUPPLY VOLTAGE230± 10% Volts, 50 / 60 Hz, AC Single Phase.-2SELECTION (MODE)All Outputs are connected through by – pass / control mode switch-3BY - PASS MODEIf “By pass” - mode is chosen then all outputs will be directly connected to the output terminals. In this option Timer is in “OFF” mode & “ON / OFF” Push button control is in “OFF”
position.-4CONTROL MODEIf “Push button” control mode is chosen then all outputs will be connected to the output terminals through the “ON/OFF” push button, according to the selection. In this option timer is in “ON”
mode.-5CURRENT OUTPUT0 to 2A AC (Measured by external Clamp meter)-6A.C VOLTAGE OUTPUT0 – 230 V AC With 2A control fuse.-7RATINGContinuous-8PROTECTIONFuse for Mains Input and all Outputs-9CONSTRUCTIONPowder coated MS Box with Carrying handle.-10DIMENSIONSW x D x H: 17.5” x 13” x 7.5” approx.-11WEIGHT23 kgs.approx.Accessories(charges applicable) :- Model : RLY – 8011. Test Cable (Current Cable) 2 Meters long with Crocodile Clip : 1 Set2. Test Cable (AC Voltage Cable) 2 Meters long with Crocodile Clip : 1 Set 3. DC Voltage Cable 2 Meters long with Crocodile Clip : 1 Set 4. Test Cable (Timer) 2 Meters long with Crocodile Clip : 1 Set5. Mains Card 2 Meter : 2 Nos.6. Spare Fuse 4 A (Main Fuse ) – 2 Nos.7. Spare Fuse 2 A (Main Fuse ) – 10 Nos.8. Instruction Manual – 1 No.9. Calibration Certificate – 1 No.
Two separate inputs & five outputs
Test outputs available:
Unit – I : 0 to 100 A, AC, 0 to 240 volts AC
0 to 240 volts DC. , Separate Variable Source
Unit – II: 0 to 2 A AC, 0 to 240 volts AC and aux.
Panel with clear and easy to follow legend.
Built in Timer for testing relays and circuit breakers.
Product Details:
Channels | Testingequipment |
Material | Plastic |
Brand | Anandha jothi |
Relay Type | Singlephase |
Current Output | 30A |
RLY 360
Product Details:
AMMETER | 3 Digit 12mm LED type Accuracy Direct reading 0 100A For current ranges of 1A 5A 10A 25A and 50A AC |
MODEL | RLY – 108 | ||
1 | SUPPLY VOLTAGE | 230 Volts , 50 Hz, (± 10%), AC Single Phase supply through Toggle switch & Control Fuse for Units 1 & 2. | |
2 | OUTPUT | 1. Variable current Application 0.6 – 100A AC 2. For voltage, the Variac output is connected to variable voltage output 0 – 230 V AC with fuse. 3. Separate current output terminals and separate voltage output terminals are provided (At one time either current or voltage circuit will be connected through a Toggle Switch) |
|
3 | CONTROLS | 1. 1ST Unit with Push Button Control Only. When the ON/OFF push button is operated, all outputs will be connected to the output connectors 2. 2nd unit with Push Button Control & By-Pass Switch |
|
4 | CURRENT OUTPUT | Output : 0.6 – 100A / 50A / 25A / 10A / 5A / 1A Each of these outputs has a separate terminal referred to one common terminal. Each current output terminal is for 400 VA capacity, except 1A output which is for 250 VA capacity |
|
5 | VOLTAGE OUTPUT | 10-230 V AC / 2A – Variable voltage output through fuse units Separate pair of test terminals is provided | |
6 | RATING | Continuous (3min ON / 10 Min. OFF) | |
7 | BRAND Get Best Price Of The Protective Relay Test Kit 109 For Rs.62000/- |
Anandha Jothi Industries |
Product Details:
Minimum Order Quantity | 1 Piece |
Usage | Industrial |
Power | 2x250VA max |
Distortion | Less than or equal to 0.8% |
Gross weight | 35kg |
Voltage | 220Volts, 50 Hz, (+/-10%) |
SUPPLY VOLTAGE | 230 10% Volts 50 60 Hz AC Single Phase |
External Timer | for checking breaker opening and closing time |
Product Details:
Distortion | Less Than or Equal To 0.5% |
Gross weight | 33 kg |
Power | 2x250VA max |
Voltage | 230 Volts (+/-10%) |
Frequency | 50 hz |
Power Source | Electricity |
Product Details:
Relay Voltage | 230V AC/230V DC |
Material | Rugged Case Plastic |
Relay Current | 30a |
Country of Origin | Made in India |
Brand | AJI |
Relay Type | Relay test kit-30A |
Current Output | 30A AC |
Product Details:
Current output | 0~45A/each phase, 0~120 |
Voltage | 20V |
DC voltage output | Value/ Range |